Laboratory equipment 1200 high pressure atmosphere tube furnace/CVD system

PRODUCT PARAMETERS

Description
REQUEST A QUOTE

Description

Overview of Tube Furnace

A tube furnace is a type of laboratory equipment used for high-temperature applications, featuring a cylindrical heating chamber designed to heat samples uniformly along its length. Commonly used in material processing, chemical analysis, and semiconductor manufacturing, it supports processes like annealing, sintering, and calcination.

Features of Tube Furnace

Uniform Heating: Ensures even temperature distribution throughout the sample.

Cylindrical Design: Facilitates consistent heating by minimizing hot spots.

Temperature Range: Capable of achieving high temperatures suitable for various processes.

Programmable Controls: Allows for precise control over heating cycles and profiles.

Gas Flow Control: Supports controlled atmosphere environments for specific reactions.

Compact and Efficient: Designed for efficient operation with minimal footprint.

Laboratory equipment 1200 high pressure atmosphere tube furnace/CVD system

(Laboratory equipment 1200 high pressure atmosphere tube furnace/CVD system)

Specification of Laboratory equipment 1200 high pressure atmosphere tube furnace/CVD system

The 1200 High Pressure Ambience Tube Furnace/CVD System is built for sophisticated laboratory applications. It reaches temperatures up to 1200 ° C. The heating elements use exceptional products for fast home heating and lengthy service life. The heater operates under high-pressure problems as much as 10 bar. This fits experiments calling for exact control of stress and ambience. The system integrates a tube heater with a chemical vapor deposition (CVD) configuration. It supports processes like thin movie development and product synthesis. The core chamber utilizes a durable quartz tube resistant to high warmth and stress. Both ends feature closed seals to keep stable internal problems. An easy to use digital user interface allows very easy change of temperature, stress, and gas circulation rates. The system auto-calibrates to preserve established criteria. Safety devices include overheat protection and emergency situation stress launch valves. These stop devices damage and ensure driver safety and security. The furnace collaborates with responsive and inert gases such as argon, nitrogen, and hydrogen. Applications span materials research, nanotechnology, and semiconductor development. Typical uses consist of sintering ceramics, covering substratums, and annealing steels. The small layout conserves laboratory area without endangering performance. Upkeep is simple with easily accessible parts and easy-cleaning surface areas. Modification options consist of different tube diameters, gas inlet setups, and sample holder styles. Heating is consistent throughout the chamber, essential for regular results. The system warms at 20 ° C per minute and cools down swiftly using integrated followers. Real-time tracking tracks temperature and stress contours. Signals trigger if values go beyond restrictions. Several gas inlets enable intricate mixtures with precise circulation control. This is suitable for layered product synthesis or oxidation studies. The sturdy building and construction lessens downtime. Technical support assists with arrangement and troubleshooting. The system provides trustworthy efficiency for both research study and industrial production.

Laboratory equipment 1200 high pressure atmosphere tube furnace/CVD system

(Laboratory equipment 1200 high pressure atmosphere tube furnace/CVD system)

Applications of Laboratory equipment 1200 high pressure atmosphere tube furnace/CVD system

The 1200 high pressure environment tube furnace/CVD system offers multiple duties in innovative material research study and industrial processes. This equipment handles high-temperature therapies under controlled gas atmospheres. It benefits synthesizing porcelains, steels, and composite products. Scientists use it to expand thin movies with chemical vapor deposition. The system supports doping procedures to modify product residential properties. It likewise makes it possible for annealing to enhance crystal framework.

The heater runs at temperature levels as much as 1200 ° C. It maintains secure pressure settings for experiments requiring specific conditions. The style includes a sealed quartz tube. This protects against contamination throughout responses. Gas circulation controls adjust atmosphere composition. Individuals can configure heating prices for steady temperature changes. This adaptability suits intricate thermal cycles.

In semiconductor manufacturing, the system down payments oxide layers or conductive films. It creates safety finishes on digital components. Nanotechnology labs use it to generate carbon nanotubes or graphene. The high-pressure feature aids in densifying products. This is essential for creating long lasting commercial components.

Academic organizations count on the furnace for studying material habits under severe heat. Industrial laboratories use it to test brand-new alloys or porcelains. The system’s consistent home heating ensures regular outcomes across examples. Safety functions include over-temperature defense and gas leakage detectors. These minimize dangers throughout long term experiments.

The tube furnace/CVD system supports inert or responsive gas environments. This allows oxidation or reduction responses as needed. Customers can tailor gas combinations for details chemical procedures. The setup suits little sets or continuous manufacturing. Its small size fits basic laboratory areas.

Upkeep includes routine cleansing of television and checking burner. Replacement components are commonly available. The system’s longevity reduces long-term costs. Energy-efficient insulation lowers power consumption. This makes it ideal for high-use atmospheres.

The equipment meets criteria for precision and integrity. It serves industries like aerospace, power, and electronic devices. Universities use it in physics, chemistry, and engineering divisions. Its adaptability addresses varied study and manufacturing needs.

Company Introduction

Welcome to Designerstudiostore, your premier source for high-quality industrial furnaces designed to meet the stringent demands of modern manufacturing. Our extensive range includes electric, gas, and oil-fired furnaces tailored for various applications such as heat treatment, forging, and laboratory use. With cutting-edge technology and innovative designs, we ensure energy efficiency and superior performance in every product. At Designerstudiostore, we prioritize customer satisfaction by offering customized solutions, reliable after-sales support, and seamless global delivery options. Explore our catalog and discover why businesses worldwide trust us for their heating needs.

If you have any questions, please feel free to contact us(nanotrun@yahoo.com).

Payment Methods

T/T, Western Union, Paypal, Credit Card etc.

Shipment Methods

By air, by sea, by express, as customers request.

5 FAQs of Laboratory equipment 1200 high pressure atmosphere tube furnace/CVD system

What is the maximum temperature the 1200 high pressure atmosphere tube furnace/CVD system can reach? The furnace reaches 1200°C. It maintains uniform heating across the entire chamber. This allows stable processing of materials like ceramics, metals, or semiconductors. The temperature control system ensures accuracy within ±1°C.

How does the system handle safety under high-pressure conditions? The furnace includes multiple safety features. Overheat protection automatically cuts power if temperatures exceed limits. Pressure relief valves prevent chamber over-pressurization. The system shuts down if gas leaks or abnormal pressure changes occur. Users must follow operational guidelines to minimize risks.

What materials can be processed in this furnace? The system works with common materials like quartz, alumina, or graphite crucibles. It supports processes involving argon, nitrogen, or hydrogen atmospheres. Reactive materials like sodium or potassium are not recommended. The chamber design resists corrosion from most gases. Check the user manual for specific material compatibility.

How often should maintenance be performed? Clean the chamber after each use to remove residue. Inspect seals and valves monthly for wear or damage. Replace heating elements if temperature fluctuations happen. Schedule professional servicing yearly to check electrical systems and gas lines. Regular maintenance prevents unexpected breakdowns.

What makes this furnace different from standard models? This system handles pressures up to 10 bar, higher than basic tube furnaces. It includes advanced gas flow controls for CVD applications. The design allows quick swaps between different atmospheres. Users can run sintering, annealing, or chemical vapor deposition in one unit. The interface simplifies setting complex temperature-pressure programs.

Laboratory equipment 1200 high pressure atmosphere tube furnace/CVD system

(Laboratory equipment 1200 high pressure atmosphere tube furnace/CVD system)

REQUEST A QUOTE

REQUEST A QUOTE