Key takeaways
- The pilot light on floor furnaces is commonly located behind the lower access panel near the gas valve.
- Always turn off the gas and wait before inspecting or relighting.
- Consult the owner's manual for the exact position on your Empire model 7067.
- A healthy pilot flame is blue; yellow or flickering flames may indicate a problem.
Where Is the Pilot Light on Empire Furnace Model 7067?
On Empire floor furnaces, including model 7067, the pilot light is typically located near the gas control valve behind the lower front access panel. Remove the panel, often secured by screws or clips, to view it. Ensure the furnace is completely off and cool before attempting any inspection. For the exact position on your unit, refer to the owner's manual provided with the furnace.

Understanding the Pilot Light System in a Floor Furnace
The pilot light is a small gas flame that ignites the main burner when the thermostat calls for heat. In a standing pilot system, the flame burns continuously. Key components include the gas supply tube, a thermocouple (or flame sensor), and the ignition source. The thermocouple generates a small voltage that keeps the gas valve open; if the pilot goes out, the valve closes to prevent gas leakage. Knowing this helps diagnose why a pilot may fail to stay lit.
On most floor furnaces, the pilot assembly is attached to the gas control valve. The flame should be blue and steady. A yellow or flickering flame may indicate dirt or air in the line. Regular visual inspection of the pilot flame is part of routine maintenance.

Steps to Access and Relight the Pilot Light Safely
To access and relight the pilot light on a floor furnace: 1. Turn off the gas supply at the shut-off valve and wait at least five minutes for any residual gas to dissipate. 2. Remove the lower access panel to expose the burner compartment. 3. Locate the pilot light assembly – it is usually a small tube with a tip near the gas valve. 4. If the pilot is out, turn the gas control knob to the 'Pilot' position. 5. Press and hold the knob (or use a separate reset button) while lighting the pilot with a long butane lighter or match. 6. Continue holding the knob for 30 to 60 seconds after the pilot lights to allow the thermocouple to heat up. 7. Release the knob; the pilot should remain lit. If it goes out, repeat the process. 8. Turn the gas valve knob to the 'On' position and replace the access panel.
Read the specific relighting instructions printed on your furnace label or in the manual. For detailed natural gas furnace venting steps, refer to our guide. If the pilot fails to stay lit after several attempts, there may be a thermocouple issue or gas flow problem requiring professional service.
Troubleshooting Common Pilot Light Problems
If the pilot light will not stay lit, the most common cause is a faulty thermocouple – it may be dirty, bent, or worn out. Clean the tip gently with fine sandpaper or replace it if necessary. A weak or intermittent gas supply can also cause the pilot to go out; check that the shut-off valve is fully open and that the supply line has no kinks.
A yellow or orange flame instead of blue indicates incomplete combustion, often due to dust or a partially blocked air opening. Clean the air intake and ensure the burner area is free of debris. If the pilot light fails to spark, the ignition system (if electronic) may need battery replacement or cleaning of the spark electrode. For complicated issues, contact a qualified technician.

Safety Tips When Working with Your Furnace
When inspecting or relighting a pilot light, turn off the gas supply at the source before removing any panels. Use only a long-reach butane lighter or a match to light the pilot – never use a cigarette lighter or open flame near gas fittings. Do not use any flammable liquids or sprays near the furnace. If you smell a strong gas odor, stop immediately, leave the area, and call a professional from outside. Keep the space around the furnace clean and free of clutter. Always verify that the water heater vent is not routed into the furnace chimney incorrectly.
Have a licensed technician perform annual maintenance to keep the pilot system and overall furnace operating safely and efficiently. Check the MPR rating for furnace filters when selecting replacements. Never attempt repairs beyond simple pilot relighting unless you have proper training and experience.

Frequently asked questions
How do I relight the pilot on my Empire model 7067 floor furnace?
General steps: turn off gas, remove lower panel, locate pilot, set gas knob to 'Pilot', depress knob, light with a long lighter, hold for 30-60 seconds, then turn knob to 'On'. Always follow the specific instructions on your furnace label or manual.
Why does my pilot light keep going out on my Empire floor furnace?
Common causes include a dirty or faulty thermocouple, a weak gas supply, or a blocked air opening. Clean or replace the thermocouple first, and ensure the gas valve is fully open. If the problem persists, contact a technician.
Is it safe to relight the pilot light myself?
Yes, if you follow safety precautions: turn off gas, wait for any gas to clear, use a long lighter, and avoid flammable materials. If you smell gas or are unsure, call a professional.